✳ Security Fit Map / NETWORK-DETECTION / Protocol v1.0

Reconstructing a sequence on a utility corporate network

An electricity distributor with a two-analyst team, much encrypted traffic, and a corporate network that must be reviewed without capturing customer payloads.

UNASSESSED · RESEARCH PROTOCOL · 2026-09-19

This edition publishes the evaluation question and work still required. It contains no scored vendor points.

What must be true

  • Sensors see the declared network segments, including encrypted traffic metadata.
  • An analyst can follow a seeded sequence to the affected hosts and accounts.
  • Evidence retention and access follow the declared data-handling limits.

Candidate scope

Two publicly documented offerings form a small pilot. Inclusion is for methodology development, not a claim that these are the only or best choices. Exact tiers and test configurations must be frozen before scoring.

OfferingScopeStatus
Vectra AI Platform (Network)The scored scope is Network detections in Respond UX with the documented network investigation workflow. Identity and cloud-log detection surfaces, Match, Stream, extended search and staffed MDR require an explicit entitlement check; do not assume the whole platform is one license.Unassessed
Capability: null
Operating: null
Open NDR with InvestigatorThe evaluated bundle is Corelight network sensors plus Investigator, not the open-source Zeek engine alone. Sensor type, collection licenses, retention, assisted-triage availability and downstream response integrations must be itemized.Unassessed
Capability: null
Operating: null

Evidence still needed

  • A frozen sensor placement and traffic volume estimate
  • Repeatable seeded-sequence and false-positive tests
  • Retention, storage, and operating effort estimates

How the evaluation will work

  1. Fix the workload, organizational assumptions, product editions, and mandatory requirements.
  2. Publish criterion-specific 0–5 anchors before collecting results.
  3. Collect reproducible observations, source dates, and operating measurements. Preserve contradictory evidence.
  4. Use the rubric below without filling unknowns with estimates.
  5. Have a second reviewer reproduce results. Publish only after both axes reach 80% coverage and critical requirements have explicit results.
AxisCriterionWeight
capabilityRequired functions40%
capabilityRepresentative effectiveness30%
capabilityEvidence and explainability15%
capabilityRequired data exchange15%
operatingStaffing and administration30%
operatingEnvironment and deployment25%
operatingIntegration maintenance20%
operatingPortability and exit15%
operatingCost predictability10%

Threshold: 70/100 on each axis. A missing-evidence interval that spans 70 prevents a definitive quadrant label. A critical failure blocks a shortlist recommendation.

Download this research protocol ↓

Find your next idea.